Choose a product category



HGST 4U60 large

HGST 4U60 JBOD Storage Enclosure - HGST 4U60

When data centers need storage expansion that delivers low power and high capacity with high-availability, they rely on the HGST 4U60 Storage Enclosure. This high-density, scalable, and cost-effective design includes 60 Ultrastar® 3.5-inch drive modules in a 4U enclosure, supports up to 8 hosts with SAS 12Gb/s performance, and delivers enterprise-class serviceability with hot-swappable components.

This integrated platform is qualified, tested and certified to support a broad range of HGST HDDs. It’s available with SAS drives for high-availability (HA) applications, with SATA drives for cost-optimized applications, and can be configured with up to twelve (12) 800GB SSDs to create separate performance tiers within the platform.

Read the HGST 4U60 Performance and Compatibility Tests by RAIDIX Testing Lab

High Density – Up to 720TB* in a 4U enclosure

Scalable – Supports 8 hosts per platform

Enterprise-class Serviceability – Hot-swappable components, cable management arm

*720TB capacity is only available with the 4U60G2 platform. Availability varies by country.



Full Name
Email
Phone
Question


Tech Specs Advanced Features Image Gallery

Model 

4U60G2 4U60

General

Host Connections

8 x 12Gbps SAS (4 per IOM)

4 x 12GBps SAS (2 per IOM)

Capacity / Physical Size

Capacity (minimum)

144TB with 6TB drive modules

96TB with 4TB drive modules

Capacity (maximum)

720TB with 12TB drive modules

600TB with 10TB drive modules

Dimensions (Enclosure)

174.8mm x 424mm x 871.2mm / 6.88in. x 16.69in. x 34.3in.

174.8mm x 424mm x 871.2mm / 6.88in. x 16.69in. x 34.3in.

Dimensions (Enclosure w/ CMAs)

174.8mm x 424mm x 1110mm / 6.88in. x 16.69in. x 43.7in.

174.8mm x 424mm x 983mm / 6.88in. x 16.69in. x 38.7in.

Weight

89.81 kg (198 lbs.) – fully configured with 60 helium drive modules

93.71 kg (208 lbs) – fully configured with 60 air drive modules

89.81 kg (198 lbs.) – fully configured with 60 helium drive modules

93.71 kg (208 lbs) – fully configured with 60 air drive modules

Power and Cooling: Operating

Power Supply

Two 1,650W PSUs, hot swap and redundant

Two 1,650W PSUs, hot swap and redundant

Input Voltage

200-240VAC auto-ranging, 47Hz-63Hz input (high line power only)

200-240VAC auto-ranging, 47Hz-63Hz input (high line power only)

Cooling Fans

N+1 redundant fans (fans integrated into PSU)

N+1 redundant fans (fans integrated into PSU)

Environmental (operating)

Temperature Range

10° to 35°C

10° to 35°C

Humidity

8% to 80% (non-condensing)

8% to 80% (non-condensing)

Shock

3.5g 6ms Pulse vertical shock

3.5g 6ms Pulse vertical shock

Vibration

Random 0.25 Grms, 5-10Hz, 0.05 g sine wave sweep, 10-300Hz

Random 0.25 Grms, 5-10Hz, 0.05 g sine wave sweep, 10-300Hz

Acoustics

<7.5dB LwA @ 23ºC

<7.5dB LwA @ 23ºC

Environmental (non-operating)

Temperature Range

-30° to 60°C

-30° to 60°C

Humidity

8% to 80% (non-condensing)

8% to 80% (non-condensing)

Shock

8g 6ms Trapezoidal

8g 6ms Trapezoidal

Vibration

Random 0.6 Grms 10-300Hz

Random 0.6 Grms 10-300Hz

Resources

HGST 4U60 JBOD Diagram
4U60 Storage Enclosure Compatibility Guide